Application scope:
1, the lowest rated operating voltage
DC4.5 -24V
2, the maximum operating current
15 mA (DC 5V)
3, operating voltage range
DC 5 to 18 V
4, load capacity
≤10 mA(DC 5V)
5, the use of temperature range
≤80°C
6, the use of humidity range
35% to 90% RH (without frosting)
7, allow pressure
Water pressure below 1.75Mpa
8, save the temperature
-25~+ 80°C
9, save the humidity
25% to 95% RH
Basic parameters
Rated voltage DC=5V Maximum operating current 15mA(DC5V)
Production Quantity PCS Inspection Standard
No. Inspection item Standard requirements
1 Appearance Product identification is clear, accurate and correct
2 Permissible water pressure <1.75MPa
3 Operating Voltage Range DC5~15V
4 Insulation resistance >100MΩ
5 Accuracy (in 2 ~ 30LMIN) ± 3%
6 Flow pulse characteristics f=(8.1*Q) Q=L/Min
7 Output Pulse Duty Cycle 50%±10%
8 output pulse high >DC 4.7V (input voltage DC 5V)
9 output pulse low level <DC 0.5V (input voltage DC 5V)